+91 9752410847 | info@lncpindore.com +91 9752410850 | admission@lncpindore.com
Pharmaceutics Laboratory

Formulation Science & Dosage Form Design

The Pharmaceutics Laboratory at Lakshmi Narain College of Pharmacy (LNCP), Indore is a state-of-the-art facility designed for comprehensive training in formulation development, dosage form design, and pharmaceutical manufacturing. The lab is equipped with modern instruments for solid, liquid, semi-solid, and sterile dosage form development.

Students gain hands-on experience in tablet compression, capsule filling, coating, granulation, and formulation of liquid orals, parenterals, and topical preparations following GMP standards.

Pharmaceutics Lab

Lab Infrastructure

Solid Dosage Form Section

Fully equipped with tablet compression machine, capsule filling machine, fluid bed dryer, rapid mixer granulator, coating pan, and multi-mill for solid dosage form development and manufacturing.

Liquid & Semi-Solid Section

Homogenizer, colloid mill, ointment filling machine, liquid filling machine, and mixing vessels for formulating syrups, suspensions, emulsions, creams, and ointments.

Sterile Formulation Section

Laminar air flow workstations, autoclave, HEPA filtered area, ampoule/vial filling, and sealing equipment for parenteral and ophthalmic product development.

Quality Control Section

Dissolution test apparatus, disintegration tester, friability tester, hardness tester, and stability chamber for in-process and finished product quality evaluation.

Major Equipment Specifications

S.No.EquipmentSpecificationsQty
1Rotary Tablet Press (Multi-Station)8-station, 20,000 tablets/hr, max 20mm diameter2
2Dissolution Test Apparatus (USP)6-station, basket/paddle, 37°C ± 0.5°C3
3Fluid Bed ProcessorTop spray/bottom spray, 1-5 kg capacity1
4Rapid Mixer Granulator5-liter capacity, variable speed1
5Stability Chamber25°C/60% RH, 40°C/75% RH, 400L2
6Laminar Air Flow (Horizontal)ISO Class 5, HEPA H14 filter3
7Autoclave (Vertical)40L, 121°C at 15 psi2
8Friability Tester25 rpm, 100 drops, digital timer2
9Disintegration Tester6-station, 37°C ± 0.5°C2
10Hardness TesterDigital, 2-200 N range3

Software & Digital Resources

  • Formulation Development Software (FormTools)
  • Dissolution Data Analysis Software
  • Stability Data Management System
  • e-Learning Modules on GMP Documentation

Safety & Compliance

  • Fire extinguishers and emergency showers
  • Chemical fume hood and proper ventilation
  • PPE including lab coats, gloves, goggles
  • Waste disposal as per environmental guidelines
Chat with us
Apply Now